Siewert Equipment
Siewert Equipment
  • Видео 38
  • Просмотров 489 621
Amphidrome System Overview - F.R. Mahony Advanced Treatment Solutions
Amphidrome® - Highest Level of Wastewater Treatment, Lowest Site Impact
The Amphidrome® system is an affordable, energy-efficient, customized onsite wastewater treatment solution designed to fit your site constraint and regulatory requirements.
Contact us: amphidrome.com
FRMahony
www.linkedin.com/company/fr-mahony-&-associates
Просмотров: 921

Видео

Blended Blower Technologies | Webinar | Siewert Equipment and Atlas Copco
Просмотров 7593 года назад
In this webinar, you will learn how to implement blended blower technologies and operate them correctly to reduce capital and operating expenses. Presented by Paul Petersen, Atlas Copco. Check out our future webinars and training offerings: www.cummins-wagner.com/state/new-york/training-events/ Contact Siewert Equipment: Website: www.cummins-wagner.com/state/new-york/ Linkedin: www.linkedin.com...
A Deep Dive into Pressure Sewer System Ownership | Webinar | Siewert Equipment and F.R. Mahony
Просмотров 1103 года назад
This webinar will provide supporting documentation of real-time costs of ownership and capital cost planning to fit the asset management goals of wastewater collection system managers. Presented by Henry Albro, F.R. Mahony. Contact Siewert Equipment: Website: www.cummins-wagner.com/state/new-york/ Linkedin: www.linkedin.com/company/siewert-equipment/ Facebook: SiewertEquipment/ Twi...
Benefits of Progressive Cavity Pumps and How they Work | Webinar | Siewert Equipment & Seepex
Просмотров 6323 года назад
This webinar goes over the basics of progressive cavity pump technology, its benefits, and its importance in the Environmental treatment industry. Presented by Chris Davis, Seepex, with Siewert Equipment (Upstate NY representative of Seepex pumps). Check out our future webinars and training offerings: www.cummins-wagner.com/state/new-york/training-events/ Contact Siewert Equipment for your pump...
Total Blower Control - Optimizing your Process Correctly | Webinar | Siewert Equipment & Atlas Copco
Просмотров 1303 года назад
In this course, you will learn about the opportunities to automate WWTP to reduce capital and operating expenditure while avoiding difficulties when implementing automation. Presented by Paul Petersen, Atlas Copco. Check out our future webinars and training offerings: www.cummins-wagner.com/state/new-york/training-events/ Contact Siewert Equipment: Website: www.cummins-wagner.com/state/new-york...
Providing a Sustainable Solution for Sewer Renewal with Pressure Sewer Systems | Siewert Equipment
Просмотров 653 года назад
This webinar covers how Pressure Sewer Collection Systems use individual residential pumps to convey wastewater flow to a central treatment system, lift station, gravity sewer, or force main. This course will cover the history, overview, advantages, considerations, and operation & maintenance of Pressure Sewer Systems. Presented by Greg Wall, Environment One. Contact Siewert Equipment: Website:...
Telemetry and Data Analytics in the Water and Wastewater Sector | Webinar | Siewert Equipment NY
Просмотров 5873 года назад
This webinar will cover telemetry & data analytics: cellular-based with alarm panel integration in the water & wastewater sector. Using telemetry, WWTPs can track (and ideally minimize/eliminate) almost ALL inflow & infiltration (I&I). In many cases, inflow and infiltration (I&I) accounts for up to 45% of the annual flow to treatment plants. Exceeding the capacity of the collection system can r...
Membrane Based Solution for CSO/SSO Treatment | Webinar | Siewert Equipment & @ovivo
Просмотров 2513 года назад
This webinar will present an alternative approach to CSO/SSO treatment using Silicon Carbide Ultrafiltration Membranes. Pilot testing data, process description, footprint, and technology comparisons will be included. Presented with Ashwini Khare and Mike Snodgrass from @ovivo. Contact Siewert Equipment: Website: www.cummins-wagner.com/state/new-york/ Linkedin: www.linkedin.com/company/siewert-e...
Metering Pump Technologies | Webinar | Siewert Equipment
Просмотров 10 тыс.4 года назад
This one hour webinar provides an overview of options in metering pump technology, which is used for chemical injection and disinfection in various stages of wastewater treatment. Presented by Jerry Connolly of Siewert Equipment. Check out our future webinars and training offerings: www.cummins-wagner.com/state/new-york/training-events/ Contact Siewert Equipment: Website: www.cummins-wagner.com...
Submerged, Attached Growth Bioreactor | Webinar | Siewert Equipment
Просмотров 9574 года назад
This webinar explains this process that utilizes a Biologically Active Filter (BAF) operating as a sequencing batch reactor. The reactor maintains a high fixed film biomass concentration averaging an equivalent of 12,000 Volatile suspended solids per liter. A system with a small footprint with superior treatment results. Presented with Eric Hess and Andrew McBrearty P.E. or F.R. Mahony. Check o...
A-B-Ease of Valve Automation | Webinar | Siewert Equipment
Просмотров 4924 года назад
This webinar will go over the why behind automating valves, types of valves we automate, history of actuators, types of gearboxes, process control strategies, and different types of valves. Presented with Jim Gannon, Flowserve Limitorque and Siewert Equipment (Upstate NY representative of Limitorque electric actuators). Check out our future webinars and training offerings: www.cummins-wagner.co...
Choosing the Right Blower Technology for Your Wastewater Plant | Webinar | Siewert Equipment
Просмотров 2064 года назад
This webinar provides an overview of each type and style of blower technology, what type of wastewater treatment plant (WWTP) should use a specific technology, and the advantages and limitations of each. Presented by Paul Petersen, Atlas Copco with Siewert Equipment (Upstate NY representative of Atlas Copco municipal blowers). Check out our future webinars and training offerings: www.cummins-wa...
Air Control in Liquid Transmission Systems | Webinar | Siewert Equipment with A.R.I. USA
Просмотров 1924 года назад
This webinar provides an overview of the various types of issues when there is air in a wastewater or water line. It will describe the different types of equipment available to remove air from a pipeline. Presented by Bill Paynter, A.R.I. USA with Siewert Equipment (Upstate NY representative of A.R.I. USA products). Check out our future webinars and training offerings: www.cummins-wagner.com/st...
Thickened Aerobic Digestion Process | Webinar | Siewert Equipment with Ovivo
Просмотров 1554 года назад
This recorded webinar is an overview of thickened aerobic digestion process technologies: G-TAD, M-TAD & Mem-TAD as well as results from existing operating plants. Presented by Bryan Woo, Ovivo with Wendi Richards, Siewert Equipment (Upstate NY representative of Ovivo products). Check out our future webinars and training offerings: www.cummins-wagner.com/state/new-york/training-events/ Contact ...
Mechanical Seal Installation for Flowserve Mark 3 Pump | Siewert Equipment | Upstate NY
Просмотров 26 тыс.4 года назад
Siewert Equipment's Mechanical Seal and Reliability Specialist, Frank Rotello, goes through a mechanical seal installation (ISC2 Cartridge Seal) for a Flowserve Durco Mark ANSI-3A pump using a demo unit. Siewert Equipment is the Upstate, NY representative for Flowserve pumps and mechanical seals. Contact us: www.cummins-wagner.com/state/new-york/mechanical-seals-ny/ Contact Siewert Equipment: W...
The Future of Disinfection On-site Hypochlorite Generation | Webinar | Siewert Equipment w/ De Nora
Просмотров 7074 года назад
The Future of Disinfection On-site Hypochlorite Generation | Webinar | Siewert Equipment w/ De Nora
New Approach to Progressive Cavity Pumping and Design | Webinar | Siewert Equipment with Seepex
Просмотров 7 тыс.4 года назад
New Approach to Progressive Cavity Pumping and Design | Webinar | Siewert Equipment with Seepex
Environment One Installation Training | Webinar | Siewert Equipment
Просмотров 4,3 тыс.4 года назад
Environment One Installation Training | Webinar | Siewert Equipment
All About Low Pressure Sewer Systems | Webinar | Siewert Equipment with Environment One
Просмотров 2,7 тыс.4 года назад
All About Low Pressure Sewer Systems | Webinar | Siewert Equipment with Environment One
Screen Selection, Hydraulics and Screenings Handling | Webinar | Siewert Equipment with Vulcan
Просмотров 6584 года назад
Screen Selection, Hydraulics and Screenings Handling | Webinar | Siewert Equipment with Vulcan
Grinder Pump Repair Specialists | Siewert Equipment | Upstate New York
Просмотров 1,2 тыс.4 года назад
Grinder Pump Repair Specialists | Siewert Equipment | Upstate New York
Timelapse of Vertical Turbine Pump Removal for Maintenance and Repair | Siewert Equipment Service
Просмотров 3 тыс.4 года назад
Timelapse of Vertical Turbine Pump Removal for Maintenance and Repair | Siewert Equipment Service
E/One Sewer Grinder Pump Startups | Service by Siewert Equipment
Просмотров 1824 года назад
E/One Sewer Grinder Pump Startups | Service by Siewert Equipment
Sewage Treatment Plant Pump Removal and Replacement | Siewert Equipment Certified Service
Просмотров 1,3 тыс.4 года назад
Sewage Treatment Plant Pump Removal and Replacement | Siewert Equipment Certified Service
Pumping, Dosing, Mixing Seminar by Siewert Equipment, October 2019
Просмотров 1694 года назад
Pumping, Dosing, Mixing Seminar by Siewert Equipment, October 2019
Siewert Equipment: Trusted Partner for Rotating Equipment | Upstate NY Pump Distributor
Просмотров 1,3 тыс.4 года назад
Siewert Equipment: Trusted Partner for Rotating Equipment | Upstate NY Pump Distributor
Pump Station Overhaul by Siewert Equipment's Certified Service Team | Gorman-Rupp Pumps
Просмотров 2234 года назад
Pump Station Overhaul by Siewert Equipment's Certified Service Team | Gorman-Rupp Pumps
SolarBee Mixer Install at Local Municipality - Siewert Equipment
Просмотров 3925 лет назад
SolarBee Mixer Install at Local Municipality - Siewert Equipment
Pump Replacement - Fountain in Dr. Martin Luther King Jr. Memorial Park, Rochester NY
Просмотров 1757 лет назад
Pump Replacement - Fountain in Dr. Martin Luther King Jr. Memorial Park, Rochester NY
BioBrane - H20 Innovation - Siewert Equipment
Просмотров 4877 лет назад
BioBrane - H20 Innovation - Siewert Equipment

Комментарии

  • @FransEsterhuizen
    @FransEsterhuizen 19 дней назад

    Can you send me the selection steps I need to take to select the sea planl for my oil refinery

  • @davidschummer
    @davidschummer 8 месяцев назад

    great job

  • @RTMEX
    @RTMEX 9 месяцев назад

    Great explanation, thank you

  • @user-ik4sq7wk1c
    @user-ik4sq7wk1c 11 месяцев назад

    Concept is absolutely clear with pipe hose example that less flow more head, But as per fundamental theory, Once you put finger your on hose then less area, LESS PRESSURE Which means low flow Law pressure, THIS IS JUST CONFUSION

  • @guyrumsey5023
    @guyrumsey5023 Год назад

    Not really the future.... Grundfos have been using this technology globally for last 15 years

  • @rolfolsen8466
    @rolfolsen8466 Год назад

    Excellent. I learnt a lot.

  • @abderabhi5155
    @abderabhi5155 Год назад

    Good job

  • @user-ok9oz3wk5x
    @user-ok9oz3wk5x Год назад

    Could pressure gauges be installed in the mechanical sea itself in order to monitor the seal chamber pressure?

    • @hamzadriss1358
      @hamzadriss1358 Год назад

      yes, you can use existing F connection of the pump or the F or PI connection from seal gland if it has been already advised to vendor.

  • @Terminxman
    @Terminxman Год назад

    I guess if you assume the pump is in perfect shape this is a good guide

  • @ericcordoves2366
    @ericcordoves2366 Год назад

    In Plan 13, how can you make the seal chamber pressure higher the suction pressure for vertical pump?

    • @nnn7369
      @nnn7369 10 месяцев назад

      Just my opinion, the pump discharge pressure is the same as the back casing where seal installed, because impeller accelerates fluid, you may look up how centrifugal pump works video made by engineering mindset!

  • @gloriousengineering7307
    @gloriousengineering7307 Год назад

    MY COMPANY MECHANICAL SEAL GLORIOUS ENGINEERING MFG OF MECHANICAL SEALING TECHNOLOGY

  • @nayrbsworld3048
    @nayrbsworld3048 Год назад

    very informative

  • @807004407
    @807004407 Год назад

    WHAT about Plan 31?

  • @taytaywilliams99
    @taytaywilliams99 2 года назад

    Love this lecture! The fact I can learn from the best in my Underware is just astounding.

  • @jeremyming933
    @jeremyming933 2 года назад

    what was load rating on cover?

  • @atiffarooq315
    @atiffarooq315 2 года назад

    Further if time to time do venting by closing discharge valve and opening discharge line drain pump start pump for short time but after some time again gas lock problem

  • @atiffarooq315
    @atiffarooq315 2 года назад

    Very very informative. We have officine meccahine metering pumps for hypo dosing having capacity of 3.5 liter/ hr at design pressure 3 barg. We always facing problem of gas lock generating from hypo.how to solve this issue?

  • @hamidkh.4229
    @hamidkh.4229 2 года назад

    What about the API Plan 65 is it possible to use with the LPG pumps as a single arrangement ?

    • @hamzadriss1358
      @hamzadriss1358 Год назад

      LPGs have higher vapor pressure meaning that your leakage will be gas and not liquid and gas tend to rise, therfore, the use of a plan 65 or B IS NOT recommended and useful.

  • @jerrysmith9780
    @jerrysmith9780 2 года назад

    Does it seem reasonable to develop a system curve for a process in a plant so you can choose the correct pumps and or verify the appropriate pumps are installed?

  • @irsanhalomoan3590
    @irsanhalomoan3590 2 года назад

    THANKS VERY MUCH FOR THE KNOWLEDGE...

  • @evgeniyzakharov9575
    @evgeniyzakharov9575 2 года назад

    Thanks!

  • @SamayalwithSaritha
    @SamayalwithSaritha 2 года назад

    Nice sharing friend

  • @killsammy_
    @killsammy_ 2 года назад

    What is polymerizing fluids?

  • @naveenpandey3255
    @naveenpandey3255 3 года назад

    sir can you explain how can we find whether primay seal is leaking or secondary seal is leaking in double seal pump? please reply

    • @oscargonzalez7857
      @oscargonzalez7857 2 года назад

      It is normal for the seals to leak, this is what they are design for. As long as there is no leak to the atmosphere, then it is normal.

  • @nigeljohn6676
    @nigeljohn6676 3 года назад

    This is very informative, Thank you for creating.

  • @Ratman_Bejo
    @Ratman_Bejo 3 года назад

    my best friend, my name is ratman from indonesia, supplier of KSB pumps, and anchovies thanks to the explanation, hopefully we can work together and this is my email: ratman@indira.co.id

  • @arishdhanam8271
    @arishdhanam8271 3 года назад

    You have a any training centre in Singapore

  • @juliojoseguzmanperez4579
    @juliojoseguzmanperez4579 3 года назад

    Vaya máquina!

  • @TuanNguyen-md8cc
    @TuanNguyen-md8cc 3 года назад

    thanks , thank thank,

  • @rakeshpawar9303
    @rakeshpawar9303 3 года назад

    Thanks for this video

  • @mahmoudabdelsalam1432
    @mahmoudabdelsalam1432 3 года назад

    great presentation ... but kindly can you install the C.C option for writing text plese ??? .. its more hlepful for nonspeakers english

    • @SiewertEquipment
      @SiewertEquipment 3 года назад

      Hello, we are sorry. We are trying to troubleshoot why the CC are not showing, but we can't get it to work on this video.

  • @Varunkm110
    @Varunkm110 3 года назад

    Thanks for information

  • @johnjestine4458
    @johnjestine4458 4 года назад

    What is semi catridge seal..? Zr100/d and zr200/d etc...

  • @carley3045
    @carley3045 4 года назад

    Where is the best place to buy seals?

  • @kumaraswamy7363
    @kumaraswamy7363 4 года назад

    Very nice good explanation sir . Thank you giving such a use information.. sir

  • @starneira
    @starneira 4 года назад

    Good information to my channel thanks

  • @frankrotello8938
    @frankrotello8938 4 года назад

    Let me be the first to Like this Ad. I especially like the part at 1:52.

  • @ram3208
    @ram3208 5 лет назад

    Sound is not clear

  • @rogerbertrand527
    @rogerbertrand527 5 лет назад

    Very nice overview. Excellent.

  • @agpsooraisoorai1757
    @agpsooraisoorai1757 5 лет назад

    Super

  • @starneira
    @starneira 5 лет назад

    good video

  • @whydahell3816
    @whydahell3816 5 лет назад

    The best on Utube. I have a test coming up for maintance/machinist/millwright at a refinery. I will be passing this alone to others for sure.

  • @srisainagaraja3808
    @srisainagaraja3808 5 лет назад

    What is full form of API

  • @raedsaad8737
    @raedsaad8737 5 лет назад

    Thank you so much very good presentation, in our plant we use plan 53-B so what is the difference between 53A and 53B ?

    • @satheeshkumar-mg6ru
      @satheeshkumar-mg6ru 5 лет назад

      53A we will have seal pot only along external pressure, but in 53B you have heat exchanger along with seal pot,the pressure of buffer fluid maintained by Accumulator..

    • @tawadhu1104
      @tawadhu1104 4 года назад

      @@satheeshkumar-mg6ru is the 53B more fragile to dirty fluid such as solid or sand compared to 53A? The pump installed in our facility has 53B seal type and the 1/2 inch flushing line between stuffing box and discharge head is frequently got burst eroded by the sand. I wonder if it can be solved by modify the sealing into 53A and permanently plug the flushing line.

    • @ghosalarghya
      @ghosalarghya 3 года назад

      53B will have bladder accumulator which 53A doesn't have. Accordingly in 53A nitrogen mixes with the fluid. But in 53B it is not the case.

    • @Varunkm110
      @Varunkm110 3 года назад

      The main difference between plan 53A and plan 53B both are pressured barier plan 53B can handle more pressure than Plan 53A . In plan 53 A manually feed nitrogen .where as in plan 53B acuumaltor and bladder make up line separately . Almost plan 53B works has stand alone unit . If plan 53B fails check the pressure of your process line . Consultant application engineer or system design engineer before changing any thing.

  • @harunhodzic1
    @harunhodzic1 5 лет назад

    Flow in pipe is constant, at beginning of presentation, no matter what cross section of pipe, velocity of water is different but flow is constant

  • @saidouneamin
    @saidouneamin 6 лет назад

    Thank you

  • @harvishsonar5265
    @harvishsonar5265 6 лет назад

    Can you please explain, @16:05 , why should one go for high powered pump, when one can get the same flow rate to the same head with a larger window of operation on a low powered pump. Why are different pumps having the same pump curve?

    • @mohamedrefaat8669
      @mohamedrefaat8669 5 лет назад

      It's only illustration image, each pump should have its own curve not the same curve, higher horsepower's curve should be above medium horsepower's curve and low horsepower's.

  • @madhusudan84mech
    @madhusudan84mech 6 лет назад

    Excellent Presentation

  • @itsjustJay863
    @itsjustJay863 6 лет назад

    Great presentation. On the plan 62, is the flush port always plugged? It appears that way on the graphic. Thanks!

    • @SiewertEquipment
      @SiewertEquipment 6 лет назад

      Hello Jay and thank you for watching. The Plan 62 is a Steam Quench on the atmospheric side of the seal. It’s used to remove solids build up like coking, or salting. The inlet should be on the top and the drain at the bottom, and YES the drain should always be left open. You can, and most people do, install a steam trap but make sure the maintenance is done on the tramp. If it plugs, the 62 will not work properly and you will fail the seal.

    • @itsjustJay863
      @itsjustJay863 6 лет назад

      Thanks but I was referring to the flush port. Looks plugged on the picture (in red)

    • @SiewertEquipment
      @SiewertEquipment 6 лет назад

      Oh I see what you’re asking, the short answer is No that port is not always plugged. That port is on the process side of the seal and can be lined up with any single seal flush plan that the seal requires, like 11 or 13. Typically you will see this called out on a spec sheet or described as: “Seal Flush Plan 11/62”.

  • @hamzadriss1358
    @hamzadriss1358 6 лет назад

    thank you so much for your efforts, very helpful